Three Common Causes of Sensor Failure, Explained
The three most common causes of sensor failure are: environmental contamination and moisture ingress; electrical overstress and electromagnetic interference; and mechanical shock, vibration, and wear. Across industries—from manufacturing and automotive to healthcare and infrastructure—these factors account for the majority of unexpected sensor outages, erratic readings, and premature end-of-life, often compounding one another under real-world operating conditions.
Contents
Cause 1: Environmental Contamination and Moisture Ingress
Moisture, dust, oils, and chemicals routinely defeat housings, seals, and coatings, leading to corrosion, leakage paths, optical fouling, and insulation breakdown. Even sensors rated for harsh environments can fail when exposure exceeds their IP/NEMA rating or when installation practices create unintended ingress routes.
How It Happens
Ingress occurs via compromised gaskets, unsealed cable entries, capillary action through wicking cables, pressure/temperature cycling that “breathes” humid air into housings, or cleaning processes and washdowns that force water past seals. Particulates and oils can occlude ports and lenses, while corrosive atmospheres attack metal traces and bond wires, accelerating failure.
Typical Signs and Diagnostics
Technicians and operators can watch for a consistent set of environmental red flags that often precede or accompany failure.
- Progressive drift or increased noise after humidity spikes, rain, or washdown cycles
- Intermittent operation that improves when the enclosure is warmed or dried
- Visible condensation, fogging on optical faces, residue on ports, or green/white corrosion products on terminals
- Lower-than-normal insulation resistance or leakage to ground
- Sluggish response in flow/pressure sensors due to blocked ports or filters
Correlating these symptoms with environmental events (e.g., cleaning, storms, seasonal humidity) helps distinguish true environmental ingress from electrical or mechanical causes.
Prevention and Mitigation
Good enclosure selection, sealing, and maintenance practices substantially reduce risk from contamination and moisture.
- Specify appropriate IP/NEMA ratings; add hydrophobic vents or breathers to prevent pressure-driven ingress
- Use proper cable glands, drip loops, and sealed connectors; avoid routing cables upward into enclosures
- Apply conformal coatings or potting where supported by the manufacturer
- Install filters, protective caps, or purge systems for ports; establish cleaning protocols that avoid high-pressure spray at seals
- Add desiccants or environmental monitoring inside enclosures in high-humidity locations
Routine inspection and timely replacement of seals and filters preserve protection levels that degrade over time due to UV, chemicals, and thermal cycling.
Cause 2: Electrical Overstress (EOS) and Electromagnetic Interference (EMI)
Voltage spikes, ESD, ground loops, and conducted or radiated EMI can damage sensor electronics outright or corrupt their signals. Events often coincide with switching transients from motors/VFDs, lightning-induced surges, hot-swapping, or improper grounding/shielding.
How It Happens
EOS burns internal protection structures or ICs via surges on power and signal lines. EMI couples into long cables, creating noise or false readings, while ground potential differences introduce offsets or cyclical errors. Poor power integrity and inadequate decoupling exacerbate susceptibility.
Typical Signs and Diagnostics
The electrical failure signature ranges from catastrophic to subtle, but several indicators are common across sensor types.
- Sudden failure after a power event, plug/unplug, or nearby lightning/surge
- Output stuck at rail (0% or 100%), excessive current draw, or no communication response
- Sporadic spikes or dropouts when large loads switch or when radios/VFDs operate
- Differences between isolated handheld measurements and system readings (hinting at ground loops)
- Visible scorching or blown transient suppressors on input boards (when accessible)
Scope captures of power rails and signals during load switching, plus isolation tests and shield continuity checks, help confirm an electrical root cause.
Prevention and Mitigation
Proper protection, grounding, and cable practices are the best defense against EOS/EMI-induced failures.
- Add surge protection: TVS diodes, series resistors, fuses/current limiting, and input clamps as specified
- Use differential signaling, twisted pairs, and shielded cables; terminate shields correctly (usually one end to avoid loops, per manufacturer guidance)
- Implement single-point grounding or equipotential bonding to minimize ground loops
- Physically separate sensor cabling from high-power lines; use ferrites and proper routing
- Ensure clean power with decoupling capacitors and, where needed, galvanic isolation
- Follow ESD-safe handling and avoid hot-plugging non–hot-swap interfaces
Documenting cable routes, grounding schemes, and protection components ensures repeatable, robust installations across sites.
Cause 3: Mechanical Shock, Vibration, and Wear
Repeated mechanical stress fractures solder joints, loosens connectors, cracks housings, and degrades bearings or diaphragms. Acute shocks from drops or impacts can instantly shift calibration or destroy fragile elements.
How It Happens
High-G events and chronic vibration excite resonances in sensor structures or mounts. Misalignment and over-torque strain housings and ports. Cable movement without strain relief transfers force to internal terminations, while rotating applications (e.g., encoders) suffer from shaft misalignment and bearing wear.
Typical Signs and Diagnostics
Mechanical issues often manifest as behavior changes tied to movement, mounting, or temperature cycles.
- Intermittent operation that changes with tapping, flexing cables, or reorienting the device
- Zero or span shifts after impacts; growing hysteresis in pressure/force sensors
- Cracked housings, loose connectors, or fretting corrosion on pins
- Unusual noise or friction in rotary sensors; accelerated failure in high-vibration zones
Replicating vibration conditions on the bench and inspecting mounts, torque marks, and cable strain points often reveals the underlying mechanical stressor.
Prevention and Mitigation
Designing for the expected mechanical environment—and verifying installation quality—significantly extends sensor life.
- Use vibration-damping mounts and specify sensors with adequate shock/vibration ratings
- Apply correct torque, alignment, and strain relief; avoid sharp cable bends and unsupported spans
- Select robust connectors with locking mechanisms; consider potting or staking for high-shock uses
- For encoders and rotating sensors, use flexible couplings and check shaft alignment regularly
- Keep sensors clear of impact zones and isolate from heavy machinery where possible
Periodic mechanical audits—checking fasteners, mounts, and cable integrity—prevent small issues from escalating into failures.
Quick Triage Checklist
When a sensor fails or behaves erratically, a focused triage can quickly differentiate environmental, electrical, and mechanical causes before deeper diagnostics.
- Verify power and signal integrity: correct voltage, ground reference, and continuity
- Inspect for moisture, corrosion, contamination, or blocked ports/lenses
- Check mounts, torque, connectors, and strain relief; gently flex to see if behavior changes
- Temporarily reroute or shield cables; isolate from nearby high-power lines
- Swap with a known-good sensor or test on a clean bench supply and short cable
- Correlate failures with events (washdowns, storms, switching loads, impacts)
This sequence narrows root cause efficiently and guides whether to prioritize sealing, protection, rerouting, or mechanical fixes.
Summary
Most sensor failures trace back to three factors: environmental ingress and contamination, electrical overstress/EMI, and mechanical shock or vibration-induced wear. Selecting the right hardware, installing it with disciplined sealing, grounding, and mounting practices, and performing periodic inspections dramatically reduces downtime and extends sensor lifespan.
What are the types of sensor failure?
The sensor failures can be classified into four categories: bias, drift, performance degradation (loss of accuracy), and freezing [10] . …
What causes sensor failure?
Dust, other contaminants, vibrations, shocks and exposure to high temperatures all have a shortening effect on the average lifespan of a sensor, so it is important to look for a solution that overcomes these problems by design, rather than just accepting frequent sensor failure and replacement as part and parcel of …
How to fix sensor problems in car?
Inspect Wiring: Check sensor connections and wiring harnesses for damage or loose connections. Replace Air Filters: A clogged air filter can damage the MAF sensor over time. Prompt Engine Repairs: Address engine problems (e.g., excessive oil consumption) to avoid harming sensors.
How much does it cost to fix sensors in a car?
However, this range can vary significantly based on several factors. For a standard passenger car, you can expect to pay between $250 and $350 for a single sensor replacement at most repair shops. Parts costs alone range from $50 to $200 per sensor, depending on your vehicle’s make, model, and year.