Home » FAQ » General » What does an occupancy sensor do?

What an Occupancy Sensor Does—and Why It Matters

An occupancy sensor detects whether people are present in a space and uses that information to automatically control systems like lighting, HVAC, and security; by turning things on when a room is in use and off (or down) when it isn’t, it saves energy, improves comfort, and informs space-planning decisions. In practice, these sensors rely on technologies such as passive infrared, ultrasonic, microwave radar, or camera-free vision to identify presence or motion, then signal building systems or smart-home platforms to act.

What Is an Occupancy Sensor?

At its core, an occupancy sensor is a presence-detection device that outputs a signal when a space is occupied and a different state when it is vacant. That signal can trigger lighting to switch or dim, ventilation to increase, thermostats to adjust setpoints, doors to lock or unlock, and software dashboards to log real-time utilization. The term “occupancy sensor” is often contrasted with “vacancy sensor”: occupancy sensors can automatically turn lights on and off, while vacancy sensors require manual-on but still turn off automatically—an approach many energy codes prefer to reduce unnecessary auto-on events.

How Occupancy Sensors Detect People

Different sensing modalities are used to infer presence, each with distinct strengths, weaknesses, and privacy profiles. Many commercial products combine multiple methods to reduce false-offs and false-ons, especially in complex spaces like open-plan offices or classrooms.

The following list breaks down common sensing technologies, how they work, and typical use cases or constraints.

  • Passive infrared (PIR): Detects changes in infrared heat patterns caused by body movement across fields of view. Pros: low cost, low power, good for line-of-sight areas like offices and corridors. Cons: can miss very still occupants; obstructed views reduce performance.
  • Ultrasonic: Emits high-frequency sound waves and listens for Doppler shifts. Pros: detects minor motion beyond line-of-sight; useful in partitioned spaces. Cons: susceptible to air movement and noise interference; requires careful tuning.
  • Microwave (RF) radar: Uses radio waves to sense motion and, in newer mmWave versions, micro-movements like breathing. Pros: strong sensitivity, penetrates some materials, improved “presence” detection. Cons: may detect motion through thin walls if not tuned; potential RF interference if poorly designed.
  • Vision/time-of-flight sensors (non-imaging or anonymized imaging): Uses depth sensing or on-device computer vision to count people and detect presence without storing identifiable images. Pros: accurate counting and presence; supports analytics. Cons: higher cost; privacy and compliance requirements apply.
  • Acoustic: Listens for human activity signatures. Pros: fill-in signal for low-motion scenarios. Cons: false triggers from ambient noise; rarely used alone.
  • CO₂/IAQ proxies: Infers occupancy from rising carbon dioxide or volatile organic compound levels. Pros: enhances demand-controlled ventilation. Cons: slow response; best as a supplemental signal.
  • Device presence (BLE/Wi‑Fi): Detects smartphones or badges. Pros: useful for desk/room booking. Cons: opt-in, privacy, and accuracy vary; not a substitute for safety-critical control.
  • Hybrid sensor fusion: Combines PIR + ultrasonic or radar + vision to balance speed, accuracy, and privacy while minimizing nuisance switching.

In practice, pairing modalities—such as PIR for low-power standby and ultrasonic or mmWave for fine presence—reduces missed detections during sedentary tasks and mitigates false triggers from HVAC airflow or passersby outside the room.

Key Applications

Occupancy sensing underpins energy efficiency, comfort, and security in homes and commercial buildings, and it’s increasingly central to post-pandemic hybrid work strategies and ESG reporting.

  • Lighting control: Auto on/off or partial-on, task tuning, and daylight harvesting deliver substantial energy savings and better user experience.
  • HVAC and ventilation: Adjusts temperature setbacks and enables demand-controlled ventilation; occupancy signals can temporarily override setbacks for comfort while minimizing runtime.
  • Security and access: Triggers alerts, locks/alarms, and visitor flow logic; helps verify after-hours occupancy.
  • Space utilization analytics: Anonymous counts inform right-sizing of real estate, hot-desking, and cleaning schedules.
  • Safety: Lights stairwells and restrooms, detects presence in restricted areas, and supports elder-care monitoring without cameras.
  • Scheduling and room booking: Detects no-shows, releases rooms, and improves meeting-space turnover.
  • Energy-code compliance: Helps meet automatic shutoff and partial-on requirements in many jurisdictions.

Across these applications, reported lighting energy savings commonly range from roughly 20% to 60%, depending on space type, occupancy patterns, and tuning; HVAC savings vary more widely but are meaningful when paired with smart setpoint strategies.

Controls and Settings That Shape Behavior

How a sensor is configured often matters as much as the hardware. The following controls determine responsiveness, comfort, and energy outcomes.

  • Auto-on vs vacancy (manual-on) vs partial-on: Auto-on lights turn on when occupancy is detected; vacancy requires a manual press to turn on but will turn off automatically; partial-on limits initial light level (e.g., 50%) to curb energy use.
  • Timeout/delay-off: The period after last detected motion before turning off; energy codes often cap this at about 20 minutes in many space types.
  • Sensitivity and detection zones: Tuning and masking prevent triggers from hallways or adjacent zones.
  • Daylight integration: Keeps lights off or dimmed when natural light is sufficient.
  • Manual override and local control: Wall controls or apps to prevent nuisance offs and improve satisfaction.
  • Presence vs motion detection: mmWave and vision-based presence can maintain “occupied” during stillness, reducing frustration in meetings or focus work.
  • People counting and thresholds: Advanced sensors can enforce max occupancy or trigger ventilation stages.
  • Privacy modes and data handling: On-device processing, anonymization, and strict retention policies mitigate privacy risk.

Good commissioning—right timeout, sensitivity, and zoning—minimizes nuisance events and delivers the intended comfort and savings.

Installation, Power, and Connectivity

Product choice and placement depend on room geometry, ceiling height, materials, and IT/security policies. The following options are common in 2025 deployments.

  • Form factors: Wall-switch replacements, ceiling mounts, and remote sensors feeding centralized controllers.
  • Power: Line-voltage wall switches; low-voltage (0–10 V/DALI) controls; Power over Ethernet (PoE) for networked luminaires; battery-powered wireless sensors (often 3–10 years life); energy-harvesting options (e.g., EnOcean).
  • Wireless protocols: Zigbee, Z-Wave, Bluetooth Mesh, Thread/Matter for consumer and light commercial; LoRaWAN and Wi‑Fi for larger footprints or backhaul.
  • Integration: BACnet/Modbus for BMS; MQTT/REST APIs for IoT platforms; lighting ecosystems such as DALI-2 and ANSI C137 standards.
  • Placement best practices: Clear line-of-sight for PIR; avoid HVAC diffusers for ultrasonic; tune radar to prevent through-wall detection; consider reflectivity and partitions.

Selecting wired vs wireless and the right protocol often comes down to project scale, retrofit constraints, cybersecurity requirements, and the need for analytics.

Codes, Standards, and Compliance Considerations

Energy and building codes increasingly require automatic shutoff and occupant-responsive controls, with exact rules varying by jurisdiction and space type. The following points summarize widely adopted expectations in North America and many other regions.

  • Shutoff timing: Many codes (e.g., ASHRAE 90.1 and IECC editions adopted by states and municipalities) limit lighting shutoff delay to about 20 minutes in common spaces such as offices, classrooms, and restrooms.
  • Vacancy or partial-on: Some spaces require manual-on or partial-on (often around 50%) to reduce unnecessary auto-on lighting, notably in California’s Title 24, Part 6 requirements.
  • Space coverage: Specific areas—classrooms, conference rooms, private offices, storage, and restrooms—frequently must have occupant sensing controls.
  • Ventilation: Demand-controlled ventilation can be driven by occupancy or CO₂ sensing under standards aligned with ASHRAE 62.1.
  • Green building programs: LEED and WELL often award credits for occupant-responsive lighting and ventilation and for providing granular utilization data.
  • Privacy and cybersecurity: Vision-based or networked sensors may be subject to GDPR/CCPA and corporate IT policies; look for features like on-device processing, data minimization, encryption, and UL 2900 or similar cybersecurity certifications.

Because code specifics change by version and locale, project teams typically verify the latest adopted edition and any local amendments before design and commissioning.

Limitations and Pitfalls

No sensor is perfect. Awareness of common failure modes helps avoid downtime and user frustration.

  • Sedentary activities: Reading or typing quietly can lead to false-offs with basic PIR; presence-capable sensors or longer timeouts help.
  • Obstructions and partitions: Furniture or glass can block or reflect signals; careful placement and masking are essential.
  • Environmental interference: HVAC airflow, fans, or vibrations may trigger ultrasonic; RF clutter can affect poorly shielded radar devices.
  • Battery and maintenance: Wireless sensors need periodic battery checks or energy harvesting to remain reliable.
  • Privacy concerns: Camera-based analytics require transparent policies and, ideally, edge processing with anonymization.
  • Overly aggressive settings: Too-short timeouts or high sensitivity cause nuisance switching and user dissatisfaction.

Mitigation typically involves sensor fusion, thoughtful placement, conservative defaults during pilot phases, and accessible manual overrides.

What’s New in 2025

Recent advances focus on better presence detection, analytics, and privacy-preserving design, enabling smarter, less intrusive control.

  • 60 GHz mmWave radar: Detects micro-movements (breathing), sustaining “occupied” status without visible motion.
  • Edge AI vision: On-device person detection and counting without storing identifiable images, improving accuracy while meeting privacy expectations.
  • Standards convergence: Wider support for Thread/Matter in residential/light commercial ecosystems alongside DALI-2 and BACnet in commercial projects.
  • Batteryless operation: Energy-harvesting wireless sensors reduce maintenance.
  • Integrated IAQ + occupancy: Combined packages drive ventilation precisely and support ESG reporting.
  • Workplace platforms: Live occupancy feeds into desk booking, cleaning schedules, and safety mustering.

These trends aim to cut false-offs, enhance comfort, and deliver actionable data without compromising privacy or adding heavy maintenance burdens.

Summary

An occupancy sensor detects whether people are present and automates building systems accordingly—most often lighting and HVAC—to save energy, enhance comfort, and improve safety. Using modalities like PIR, ultrasonic, radar, or privacy-preserving vision, today’s sensors integrate with building controls and analytics platforms, help meet energy codes, and inform real estate decisions. Performance depends on the right technology mix, placement, and commissioning, with modern systems increasingly favoring sensor fusion and edge processing to balance accuracy, convenience, and privacy.

What are the benefits of occupancy sensors?

Benefits of occupancy sensors include energy savings, cost reduction, better space utilization, and heightened security. Ideal applications span offices, retail spaces, and industrial facilities, where they integrate with IoT systems to optimize operations.

Where are occupancy sensors required?

Occupancy sensors are often required by building codes in intermittently used spaces like classrooms, conference rooms, private offices, restrooms, storage rooms, break rooms, corridors, and stairwells, though specific requirements vary by jurisdiction and code. Codes like those from the International Green Construction Code (IgCC) and the California Energy Commission mandate these controls to ensure lighting is automatically turned off when spaces are vacant, reducing energy consumption.
 
Commonly Required Spaces

  • Private and Public Offices: For enclosed offices, conference/meeting rooms, and break rooms. 
  • Education and Healthcare: Classrooms, lecture rooms, training rooms, and telemedicine rooms. 
  • Storage & Support: Storage rooms, janitorial closets, and medical supply rooms. 
  • Restrooms: Mandatory in most building codes for automatic shut-off. 
  • Corridors & Stairwells: Especially in larger commercial buildings, to reduce lighting when not in use. 
  • Small Enclosed Spaces: Any space 300 sq. ft. or less, enclosed by floor-to-ceiling partitions. 

Key Considerations

  • Code-Dependent: The most important factor is the specific local, state, and federal building codes that are in effect. 
  • Intermittent vs. Constant Use: Sensors are most effective and cost-efficient in areas with unpredictable or intermittent occupancy patterns. 
  • Types of Sensors: Depending on the space, you may use either an occupancy sensor (which can turn lights on automatically) or a vacancy sensor (which requires manual turn-on). 
  • Energy Efficiency: The primary reason for these requirements is to save energy by automatically turning off lights when a space is vacant. 

Is an occupancy sensor a camera?

No, typical occupancy sensors do not have cameras; they use technologies like passive infrared (PIR), ultrasonic waves, or radar to detect presence without capturing video or identifiable information. While some specialized devices might integrate cameras or work with separate camera systems for more detailed analysis, standard occupancy sensors are designed for privacy by collecting anonymous data to control building systems or provide analytics.
 
This video explains the difference between occupancy and vacancy sensors and where they are used: 54sMEP AcademyYouTube · Oct 24, 2022
How Occupancy Sensors Work (Without Cameras)

  • Passive Infrared (PIR) Sensors: Opens in new tabDetect the heat signatures of people in a space by sensing changes in infrared radiation, like people moving in or out of the sensor’s field of view. 
  • Ultrasonic Sensors: Opens in new tabTransmit sound waves at high frequencies and detect changes in the return signal caused by movement or occupancy. 
  • Radar-Based Sensors: Opens in new tabEmit microwaves or other waves and detect when these waves are disrupted or reflected differently due to the presence of people or objects. 

Why They Don’t Have Cameras

  • Privacy: The primary function of occupancy sensors is to provide data on space utilization without compromising employee privacy, a key reason they avoid image-based recognition. 
  • Efficiency: Cameras are not necessary for their core purpose of detecting presence or motion for energy management, building automation, or workspace analytics. 
  • Cost and Complexity: Integrating cameras would add significant cost and complexity to devices primarily designed for sensing presence, not visual monitoring. 

When Cameras Are Used With Occupancy Sensors

  • Integrated Security Systems: Opens in new tabOccupancy sensors can be used in conjunction with separate camera systems to trigger recordings when motion is detected, enhancing security without the sensor itself being a camera. 
  • Advanced AI & Analytics: Opens in new tabSome advanced systems may use cameras to gather more detailed data, transforming security cameras into AI agents capable of tasks beyond simple motion detection. 

What does the occupancy sensor do?

Occupancy sensing technology detects the presence of people in a room or space. Occupancy sensing is a function of several types of sensing technology, including Wireless Sensing, Ultrasonic Sensing, and PIR. Critical applications for occupancy sensing include energy management, home security, and healthcare.

T P Auto Repair

Serving San Diego since 1984, T P Auto Repair is an ASE-certified NAPA AutoCare Center and Star Smog Check Station. Known for honest service and quality repairs, we help drivers with everything from routine maintenance to advanced diagnostics.

Leave a Comment