Home » FAQ » General » What is the occupancy classification system?

What the Occupancy Classification System Is—and Why It Matters

The occupancy classification system is the code-based method that categorizes buildings by their intended use and relative risk so that designers and officials can apply the right life-safety, fire-protection, egress, and structural requirements. In practice, it’s how building and fire codes decide what a facility must have—sprinklers, alarms, fire ratings, exits, accessibility features, and more—based on what happens inside and who is there.

What “occupancy classification” means in building codes

In most jurisdictions, occupancy classification is defined by model codes such as the International Building Code (IBC, 2024 edition) and the NFPA 101 Life Safety Code (2024 edition), then adopted (sometimes with amendments) by states or local authorities. Though terminology and group names vary between codes and countries, the core idea is constant: match the building’s use to a risk category that drives minimum safety provisions.

How the system works

Authorities Having Jurisdiction (AHJs) review a project’s proposed use and characteristics—such as occupant load, mobility and supervision needs, fire load, and building size—to assign an occupancy group. That classification then links to prescriptive or performance-based requirements for egress capacity, fire resistance, fire detection and suppression, structural loads, and other safeguards.

Main occupancy groups you’ll see (IBC)

The following list summarizes the primary occupancy groups under the 2024 International Building Code, which is widely adopted in the United States and referenced internationally.

  • Assembly (Group A: A-1 through A-5) — Theaters, restaurants, stadiums, places of worship.
  • Business (Group B) — Offices, outpatient clinics, testing/labs without high hazard.
  • Educational (Group E) — Schools for K–12 (daytime), certain day-care uses.
  • Factory/Industrial (Group F: F-1 moderate hazard, F-2 low hazard) — Manufacturing, processing.
  • High Hazard (Group H: H-1 through H-5) — Significant quantities of flammable, explosive, or toxic materials.
  • Institutional (Group I: I-1 through I-4) — 24-hour care, hospitals, nursing homes, detention/correctional.
  • Mercantile (Group M) — Retail stores, markets, showrooms.
  • Residential (Group R: R-1 through R-4) — Hotels, apartments, dormitories, small assisted living.
  • Storage (Group S: S-1 moderate hazard, S-2 low hazard) — Warehouses, self-storage, parking garages.
  • Utility and Miscellaneous (Group U) — Sheds, towers, greenhouses, small accessory structures.

These groups are further refined by subcategories (for example, A-2 for food and drink, I-2 for hospitals) to align specific hazards and occupant vulnerabilities with tailored safety measures.

NFPA 101 Life Safety Code categories

Some jurisdictions and facilities use NFPA 101, which structures occupancies a bit differently but with the same intent: align building features with life-safety needs.

  • Assembly, Educational, Day-Care
  • Health Care and Ambulatory Health Care
  • Detention and Correctional
  • Residential (One- and Two-Family, Lodging/Rooming, Apartment)
  • Mercantile and Business
  • Industrial and Storage
  • Special structures (e.g., high-rise provisions, malls) and mixed occupancies

While nomenclature differs from the IBC, designers crosswalk the two systems to ensure all required life-safety features are met in the adopted code environment.

Key factors used to classify a building

When deciding an occupancy classification, code officials consider several practical criteria to capture both how a building is used and the risks present.

  • Primary function and activities (e.g., dining, sleeping, treatment, manufacturing).
  • Occupant load and density (from code tables based on floor area and use).
  • Occupant characteristics (age, mobility, need for supervision or restraint).
  • Fire and fuel load (materials stored/used; presence of flammables or toxics).
  • Building size and height (number of stories, fire area, construction type).
  • Continuity of operation and evacuation complexity.
  • Presence of fire protection (automatic sprinklers, alarms) and compartmentation.

Taken together, these inputs guide AHJs to a classification that accurately reflects real-world risk and informs the necessary safety features.

What classification controls in design and permitting

Once an occupancy is assigned, it drives a cascade of code requirements that the project must satisfy before permits are issued.

  • Egress quantity, width, travel distances, exit separation, and stair enclosures.
  • Fire-resistance ratings for structural elements, shafts, and tenant separations.
  • Fire detection and alarm systems, sprinkler thresholds, and smoke control.
  • Allowable building height, area, and construction type limitations.
  • Accessibility provisions and plumbing fixture counts based on occupant load.
  • Special systems (e.g., hazardous exhaust for H occupancies; nurse call for I-2).

These requirements are interdependent; a change in occupancy can raise or lower thresholds, affecting cost, layout, and even project feasibility.

Mixed and accessory occupancies

Many buildings contain more than one use. Codes provide structured methods to handle this without over- or under-protecting the building.

  • Accessory occupancies — Small, incidental uses (e.g., a storage room in an office) permitted without being classified separately if under set area limits.
  • Incidental uses — Rooms with specific hazards (e.g., boiler rooms) requiring targeted protection (ratings, sprinklers) but not a separate occupancy.
  • Nonseparated mixed-use — Treat the whole floor or building by the most restrictive occupancy, with shared protection levels.
  • Separated mixed-use — Use fire barriers and apply each occupancy’s rules to its area, coordinating egress and other shared systems.

Choosing the right mixed-use strategy can streamline compliance and reduce construction cost while maintaining safety.

Determining occupant load—and why it matters

Occupant load is calculated from code tables that assign a load factor (people per square foot) to each use, then adjusted for fixed seating or standing areas. It directly affects egress size, door hardware, alarm requirements, and sometimes sprinkler triggers.

  • Assembly dining areas often use 15 net sf/person; concentrated assembly can be 7 net sf/person.
  • Offices commonly use 150 gross sf/person; classrooms 20 net sf/person (values vary by code table).
  • Fixed seating uses seat counts; pews and bleachers have specialized calculations.

Accurate occupant load ensures exits, stairs, and life-safety systems are sized to real demand during emergencies.

Examples: how a space is classified

These quick scenarios illustrate how the same building shell can yield different classifications based on use.

  • A restaurant with dining room and bar: Group A-2 (assembly for food/drink).
  • A multi-tenant office floor: Group B (business).
  • A public elementary school: Group E (educational).
  • A hospital with 24/7 medical care: Group I-2 (institutional).
  • A medium-hazard warehouse storing plastics: Group S-1; a parking garage: S-2.
  • A lab with significant flammable liquids: likely Group H (subgroup depends on quantities/controls).
  • An apartment building: Group R-2; a hotel: Group R-1.

Small plan changes can shift classification—adding overnight stays, for example, can move a project from Business to Residential or Institutional with major code implications.

Change of occupancy: a frequent renovation trigger

When a building changes use (say, warehouse to event space), codes treat it as a “change of occupancy,” often requiring upgrades to egress capacity, sprinklers, fire ratings, and accessibility—even if the structure remains the same.

  • Documentation: establish existing vs. proposed occupancy and construction type.
  • Gap analysis: identify added life-safety requirements triggered by the new use.
  • Alternate methods: performance-based designs may provide compliant, cost-effective solutions.

Early coordination with the AHJ helps avoid surprises and supports phased or alternative compliance paths where allowed.

Global context and local variations

Beyond the IBC and NFPA 101 used widely in North America, other regions use analogous systems—such as the UK’s purpose groups within Approved Document B or Australia’s NCC Classifications. While categories differ, the underlying logic is the same: classify by use and risk to assign safety measures.

  • Terminology and thresholds vary by country and even by local amendments.
  • Always verify the adopted code edition and local interpretations with the AHJ.

Design teams working across jurisdictions should map classifications between codes and confirm any local deviations early in design.

Recent code cycle notes (through 2024)

The 2024 IBC and 2024 NFPA 101 maintain the established occupancy families while refining related provisions—such as allowances for modern construction materials, updated egress and fire-protection details, and clarifications on mixed and accessory occupancies. While the group names remain consistent, specific thresholds, definitions, and special-case rules evolve; always consult the adopted edition and local amendments.

Who uses the system—and when

Occupancy classification is central from concept through operations.

  • Architects and engineers: to size egress, select construction type, and design protection systems.
  • Developers and owners: to understand feasibility, cost, and operational constraints.
  • Contractors: to plan construction means, phasing, and inspections.
  • AHJs: to review, permit, and inspect for compliance and ongoing safety.
  • Facility managers: to maintain compliance during tenant fit-outs and changes of use.

Because classification underpins so many requirements, getting it right early helps prevent redesigns, delays, and expensive retrofits.

Bottom line

The occupancy classification system is the backbone of life-safety strategy in building regulation. By matching a building’s use and risks to clear requirements, it enables consistent, enforceable protection for occupants and first responders while giving designers a roadmap to compliance.

Summary

Occupancy classification is a code-defined framework that groups buildings by use and risk to set requirements for egress, fire protection, construction limits, and more. Under the IBC (A, B, E, F, H, I, M, R, S, U) and NFPA 101 (assembly, educational, health care, detention/correctional, residential, mercantile, business, industrial, storage), classifications hinge on activities, occupant load, hazards, and building characteristics. The assigned group affects virtually every design decision, especially for mixed-use projects and when changing use. While core categories are stable through 2024 editions, details vary by jurisdiction and code cycle, so coordination with the AHJ and the adopted code is essential.

What are the 5 occupancy categories of structures?

It describes classifying structures based on their occupancy and nature into five categories – Essential Facilities (Category I), Hazardous Facilities (Category II), Special Occupancy Structures (Category III), Standard Occupancy Structures (Category IV), and Miscellaneous Structures (Category V).

What is an occupancy classification?

An occupancy classification formally designates a building’s or space’s primary purpose, used by building and fire codes to determine appropriate safety requirements based on the associated hazards and risks. These classifications, such as Assembly, Business, and Residential, are based on factors like the number of people, their familiarity with the space, and whether they are awake or asleep. The classification is essential for establishing rules for fire protection, structural design, and means of egress, ensuring that buildings with different uses have different and appropriate safety standards. 
Why Classifications Are Important

  • Risk Assessment: Different occupancies present different risks. For example, a crowded assembly hall has different safety needs than a sparsely populated warehouse. 
  • Code Application: The occupancy classification is the primary step in applying building codes, such as the International Building Code (IBC) or NFPA codes, to determine necessary fire protection, construction type, and egress requirements. 
  • Design Load: The classification also affects the required structural design loads, including those for flood, wind, snow, and seismic activity. 

Common Occupancy Types (Examples from IBC)
Model codes like the IBC group buildings into major occupancy categories: 

  • Assembly (A): Places where people gather, such as theaters or restaurants.
  • Business (B): Offices and professional services.
  • Educational (E): Schools and child-care facilities.
  • Residential (R): Homes, apartments, and other dwellings.
  • Institutional (I): Buildings where people are in care or confinement, such as hospitals or detention facilities.
  • Mercantile (M): Shops and stores where people shop.
  • Factory/Industrial (F): Buildings for manufacturing and industrial processes.
  • Storage (S): Buildings for storing materials.
  • Utility and Miscellaneous (U): Other structures like garages or miscellaneous buildings.

How a Classification Is Determined

  • The building’s owner or designer determines the primary use of the building. 
  • This usage is then matched to the appropriate occupancy group defined in the relevant building code. 
  • Local authorities having jurisdiction (AHJ) review building plans and conduct inspections to ensure compliance with the code requirements for the determined occupancy classification. 

What is an occupant classification system?

The Occupant Classification System (OCS) is designed to meet the regulatory requirements of Federal Motor Vehicle Safety Standard (FMVSS) 208 and is designed to disable (will not inflate) the passenger’s side front airbag under certain conditions.

What is the difference between S-1 and S-2 occupancy?

S-1 occupancy involves storing combustible or flammable materials like furniture, paper, and tires, while S-2 occupancy involves storing noncombustible, non-flammable materials like cement, glass, and fresh foods. This distinction is crucial in building codes (such as the International Building Code) for fire safety, dictating different design and protection requirements based on the fire hazard posed by the stored materials. 
Group S-1: Moderate-Hazard Storage

  • Materials Stored: Combustible and flammable materials that can create fire and smoke. 
  • Examples:
    • Aircraft hangars 
    • Books, paper, and furniture 
    • Tires 
    • Clothing and furs 
    • Motor vehicle repair garages 
  • Key Characteristic: Materials are capable of burning or producing fire. 

Group S-2: Low-Hazard Storage 

  • Materials Stored: Noncombustible, non-flammable materials. 
  • Examples:
    • Cement 
    • Glass 
    • Electrical coils and motors 
    • Beverages with low alcohol content (up to 16%) 
    • Fresh fruits and vegetables 
    • Dairy products 
    • Dry cell batteries 
  • Key Characteristic: Materials do not ignite easily or contribute significantly to a fire. 

Why the Distinction Matters

  • Fire Hazard: The primary difference is the fire hazard posed by the stored materials. 
  • Building Codes: The classification determines the applicable building and fire codes, which in turn dictate requirements for fire protection, sprinkler systems, and building construction. 
  • Safety: Proper classification ensures that buildings are designed with appropriate safety features to handle the specific risks associated with the stored items. 